SPARE PARTS Fig.A
Parts such the valve, the piezo-electric device and the gas pipes may be substituted easily. To substitute these parts, procede
as follows :
•
Valve - After removing the front protection, loosen the screw fittings of the gas connections (6-7-8-16) and substitute
the broken parts with the new ones.
•
To substitute the thermocouple, unscrew the pilot burner connection (1) as well as the thermocouple connection (7)
and substiutute the part.
•
The ignition spark plug (2) must be unscrewed and substituted.
INSTRUCTIONS FOR USE
Warning!:
Before turning on the appliance, clean it with water and and dish-washing detergent. Rinse it several times and fill it with
water to the maximum level
IGNITION OF THE MAIN BURNER
Ignition of the pilot burner Fig.A
Rotate knob (A) from position "0" to position
(18). The flame ignites automatically and is visible through the inspection window in the front panel.
After ignition keep the button (A) pressed for another 5-10 seconds, to allow the thermocouple to heat, then release.
If the flame goes out, repeat the procedure.
Ignition of the main burner and temperature regulation Fig.A
After releasing the button (A), rotate it to position
By rotating the knob further to the position
Turning off the main burner
Rotate the knob to the
position. Only the pilot burner will remain lighted.
Turning off the appliance Fig.A
Rotate the knob to the "0" position. This command blocks the gas flow to both the main burner and the pilot burner. To ignite
the appliance again, rotate the knob to the
FILLING THE TUB
Rotate knob (A) of the drainage tap from the closed position
tub indicates
EMPTYING THE TUB
In order to do this you must open the cabinet doors and rotate the knobof the ball valve anti-clockwise.
INSTRUCTIONS FOR REMOVAL OF EXHAUST GASES
Type "A" Appliances (See Data Plate)
Combustion fumes from type " A" appliances must be removed by means of special hoods or similar devices which are
connected to efficient flues or stovepipes or directly to the outside (natural removal). Fig. 1.
If this is not possible, an extraction fan may be used if it is connected directly to the outside (mechanical removal). Fig.
2. The capacity of such a fan shall not be inferior to that established by regulations in effect.
Mechanical Removal of Exhaust Gases
The supply of gas to the appliance must be directly linked to the exhaust removal system. It must be interrupted if the capacity
of the system falls below the minimum amount established by the regulations in force.
The gas supply to the appliance must be turned on again manually.