Idrabagno ESI
3
INSTALLATION
3.1 Standards
The use of gas appliances is subject to strict regulations. It is therefore
important that the UNI 7129 and 7131 standards are observed.
For liquefi ed petroleum gas (LPG), the installation must comply with the
requirements of the distributing companies and with the requirements of
the standards cited above.
The appliance is sold without the inlet and outlet device as a different device
is required according to the specifi c installation; please consult the acces-
sories catalogue to request any of the various different devices.
3.2 Wall mounting
The appliance must be installed on a suitable wall:
- the device should not be closed in a unit or niche; there should be a gap
of at least 20 mm between the side walls and the appliance, so as to
facilitate maintenance work;
20
- once the position of the appliance has been decided on, make two 8 Ø
holes 320 mm apart for the support template (use the same template to
mark the holes); fi x with the plugs provided. The most common type of
rear and horizontal outlet is described below; guide the wall template fi ns
into the slots on the paper template;
- mark the centre of the fl ue hole;
- make a 110 mm Ø hole as shown on the paper template;
IDRABAGNO 11-13 ESI
22
20
200
IDRABAGNO 17 ESI
- cut the pipes to the correct length according to the thickness of the wall. If
done correctly, the 60 mm Ø fl ue should protrude by 7.5 mm with respect
to the 100 mm Ø air duct;
- insert the specifi c fl ue made up of two concentric pipes in the hole in the
wall;
E
D
C
A
B
C
D
= trim ring seat
E
- seal the gap between the 100 Ø pipe and the hole in the wall with ce-
ment-based mortar, positioning a piece of paper so that the tube does not
remain fi xed to the wall itself, so as to facilitate subsequent disassembly.
Place the appliance in the chosen position, with reference to the meas-
urements indicated in this instruction manual in the " "2.1 Appliance parts/
Size and connections" " section.
3.3 Positioning
- The appliance should be installed on a suitable wall and it is essential
that the minimum spaces be left around it to allow for maintenance work
to be performed (see "3.2 Wall mounting" section).
- The appliance should not be positioned above a stove or other cooking
appliance so as to avoid kitchen vapour grease being deposited on it and
affecting operation.
- Heat-sensitive walls such as those made from wood should be protected
with suitable insulation.
B
A
= fl ue gas pipe
= inlet pipe
= rubber trim ring
= end piece