7. OPERATION
a) Connect the charger to the battery.
b) Connect the charger to the AC mains.
c) Charging will start: the red LED will switch on.
d) When the battery is fully charged the green LED will switch on.
Note 1: When disconnecting the charger from the battery, it is allowed to leave the mains plug in
the wall socket. The green LED will be on.
When connecting to the battery the green LED will switch off and the red LED will switch on.
Exception: if the battery is (nearly) fully charged the green LED will remain on.
Note 2: Both LEDs will blink in case of an error.
Note 3: If the charger is connected to the AC mains (b) but no battery was connected (a) the red LED
will blink. When there is still no battery connected after +- 30min the charger will switch to Float.
Then the red LED will switch off and the green LED will switch on.
Attention: If a battery is connected and charging is interrupted, this cannot be detected by the
charger. The charger will indicate Charging (red LED on) or Full (green LED on).
8. INDICATIONS
Charger off (mains not connected)
Charger on (mains connected)
Charging
Full
Error
= LED off
= LED on
= LED blinking
6
Red LED
Green LED
Note
Bulk, Absorption, no battery detected
Bulk, Absorption, battery detected
Float, Storage, Repeated absorption
No blinking codes. Possible errors:
Short circuit
•
Reverse polarity
•
Over-voltage
•