AC Current
Range
* 6 mA
60 mA
600 mA
6 A
60 A
100 A
* Digit rolling ±3 digits.
Frequency Response (61~400 Hz) :
Position Error:
Additional Accuracy by Crest Factor (C.F.):
Max. Crest Factor:
Influence of external magnetic field of adjacent wires :
Low Pass Filter
Range
* 6 mA
60 mA
600 mA
6 A
60 A
100 A
* Digit rolling ±3 digits.
Attenuation characteristic:
Cut-off frequency :
megger.com
Resolution
0.001 mA
0.01 mA
0.1 mA
0.001 A
0.01 mA
0.1 A
0A ~ 10A
±(2% reading + 11 digits)
10 ~ 50A
±(10% reading + 11 digits)
50 ~ 100A
±(35% reading + 11 digits)
±1% of reading.
Add 1.0% for C.F. 1.4 ~ 2.0.
Add 2.5% for C.F. 2.0 ~ 2.5.
Add 4.0% for C.F. 2.5 ~ 3.0.
1.6 for 6000 ~ 5000 digits
2.0 for 5000 ~ 3000 digits
3.0 for 3000 ~ 0 digits
0.04% typical value.
Resolution
0.001 mA
0.01 mA
0.1 mA
0.001 A
0.01 A
0.1 mA
approximately –24 dB/octave
100 Hz
Accuracy
0A ~ 10A
±(1% reading + 8 digits)
10 ~ 50A
±(2% reading + 10 digits)
50 ~ 100A
±(10% reading + 10 digits)
Accuracy
0A ~ 10A
±(2% reading + 8 digits)
10 ~ 50A
±(3% reading + 10 digits)
50 ~ 100A
±(12% reading + 10 digits)
15