INSTALLATION - CRHQD250T, Q SERIES, B23 SERIES,
PCSD25RT, CRHSD25RT AND FBD400 SERIES
19. Push the rocker switch into the control
panel (see Figure 35).
Figure 35 - Installing Rocker Switch
A 15 amp, 120 Volt, 60 Hz circuit with a
properly grounded outlet is required. The
fireplace should be on a dedicated circuit.
Other appliances on the same circuit may
cause the circuit breaker to trip, or the fuse to
blow when the heater is in operation. Plan the
installation to avoid the use of an extension
cord. Extension cords are for temporary use
only. If an extension cord must be used, it must
be UL/CSA certified, rated at 10A (1250W),
125V maximum with 16 AWG minimum and
constructed of two current carrying conductors
with ground. A heavy duty extension cord with
the shortest length possible for the connec-
tion is recommended and must not be longer
than 50 ft. (15.2 m). Do not coil or cover the
extension cord.
200070-01A
ELECTRICAL CONNECTION
www.usaprocom.com
20. Reattach the control panel and log bracket
(if applicable) with screws removed in step
15 (see Figure 31, page 12).
21. Reinstall logs according to original layout.
Refer to owner's manual for log place-
ment.
22. CRHQD250T and Q Series Replace grill
with 2 screws removed previously (see
Figure 30, page 11).
For other models, close stove door.
23. Check all wires, then replace blower ac-
cess panel (see Figure 18, page 9).
WARNING: Electrical outlet
wiring must comply with local
building codes and other appli-
cable regulations to reduce the
risk of fire, electrical shock and
injury to persons.
WARNING: Do not use this
fireplace if any part of it has been
under water. Immediately call a
qualified service technician to
inspect the fireplace and replace
any part of the electrical system
which has been under water.
13