Dyna-Glo DGPH201BR El Manual Del Propietario página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CARE AND MAINTENANCE
Signs of possible blockage include:
Gas odor with extreme yellow tipping of flame.
Heater does NOT reach the desired temperature.
Heater glow is excessively uneven.
Heater makes popping noises.
Spiders and insects can nest in burner or orifices. This dangerous condition can damage heater and
render it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may
help clear away smaller particles.
Carbon deposits may create a fire hazard. Clean dome and burner screen with warm soapy water if
any carbon deposits develop.
Battery check: Please ensure the battery is installed before use. Take out the battery if the unit will
not be used for a long time.
Note: In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal.
Frequently check for corroded areas and repair them promptly.
TIP:
Use high-quality automobile wax to help maintain the appearance of your heater. Apply to exterior
surfaces from the pole down. Do not apply to emitter screen or domes.
Storage
Between uses:
Turn off control valve and cylinder valve.
Disconnect the hose regulator from propane cylinder.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain,
sleet, hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Note: Wait until heater is cool before covering.
During periods of extended inactivity or when transporting:
Turn off control valve and cylinder valve.
Turn control knob off.
Remove the battery from the ignitor.
Disconnect the hose regulator and move the cylinder to a secure, well ventilated outdoor location.
Store heater upright in an area sheltered from direct contact with inclement weather (such as rain,
sleet, hail, snow, dust and debris).
If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Never leave LP cylinder exposed to direct sunlight or excessive heat.
Note: Wait until heater is cool before covering.
Service
Only a qualified service person should repair gas passages and associated components.
Caution: Always allow heater to cool before attempting service.
17

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dgph202ssDgph101brDgph102ss

Tabla de contenido