Fig. 5.5 Frames with gravel trays
Fig. 5.6 Direct screwed connection
Fig. 5.7 Fixing and blocking the mounting rail
Installation manual auroTHERM 0020057143_04
Flat roof installation 5
If gravel trays are used:
• Place large protection mats under the sy-
stem.
• Assembly frames based on the number of
collectors to be installed.
a
Caution!
Before mounting the collectors, fill
the gravel trays on the first frame
with gravel or other suitable
weighting material, to give the sy-
stem stability.
h
Note
For load weights and distances,
please see Tab. 5.1 and 5.2.
With screwed connection to the flat roof:
• Assembly frames based on the number of
collectors to be installed.
Note
h
For load weights and distances,
please see Tab. 5.1 and 5.2.
• Fix the frames on the roof.
a
Caution!
The roof skin can break and cause
lack of tightness!
When installing the roof sealing sur-
faces, make sure the roof skin is ade-
quately protected.
• Fix the horizontal mounting rails to the
frame clamping elements.
• Compensate any difference in height by
moving the clamping elements.
• Pull the lower part of the clamping element
upward, now it can be moved and it enga-
ges again when released.
GB