Descargar Imprimir esta página

Hayward AquaVac 500 Serie El Manual Del Propietario página 17

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting - Power Supply:
Warning: Do not attempt to repair the power supply. There are no user serviceable parts.
Symptom
No Power, power
supply indicators
do not light
Cleaner does
not operate.
All power supply
indicators flash,
cleaner does not
operate
HAYWARD only warranties the quality, performance and safety of its products when assembled with genuine
Hayward manufactured parts. Use of non-genuine Hayward manufactured parts will void all warranty.
Possible Solutions
Make sure that the power supply is plugged into a
functioning GFCI outlet. Reset GFCI if necessary. Note:
Repeated GFCI trips may indicate a faulty GFCI or non-
repairable failure of the power supply. In such case,
discontinue use of the power supply.
Make sure that the service circuit breaker or fuse have
not tripped.
It may take up to 1 minute from the start of a cleaning
cycle for the cleaner to begin moving. Make sure that a
cleaning cycle has been initiated.
A problem was detected with the power supply. The
flash pattern identifies the type of problem.
*1 flash every 3 seconds: Overcurrent Detection: This may
happen if debris becomes lodged in the impeller or drivetrain of the
cleaner. A damaged cleaner cable is also a potential cause of this
issue. This fault can be cleared by unplugging the power supply
from the utility power for at least 1 minute.
*
2 flashes every 3 seconds: Over Temperature Detection. The
failure will automatically reset and a cleaning cycle will commence
when the power supply cools down. Place the power supply upright
with the heatsink away from a wall or surface. Keep the power
supply out of direct sunlight.
3 flashes every 3 seconds: Unplug the power supply from the
*
utility power. Wait at least 1 minute to reset the fault. Make sure
the cleaner cord is not plugged into the power supply. Plug the
power supply power cord into the electrical outlet. Set the power
supply to start a cleaning cycle. If this fault repeats, the problem is
with the power supply. Otherwise, there is a problem with the
cleaner or the cleaner cord.
17

Publicidad

loading