2. PARTS OF THE STERILISER
A. Handle
B. Lid
E. Large basket with rack
(only for electric sterilising)
H. Electrical unit
(only for electric sterilising)
I. ON/OFF button
J. LED light
M. Tongs
3. INSTRUCTIONS FOR USE
3.1. ELECTRIC STERILISING:
(with the basket for the large size or without the basket for the small size)
C. Steam outlet
BEFORE USING THE APPLIANCE FOR THE FIRST TIME, IT IS IMPORTANT TO KNOW THAT:
- Never switch on the unit without water inside the water tank.
- Remember to remove the Microwave base (L) from the Electrical (H) unit before switch on the product
- The appliance begins to produce steam 4 minutes after the sterilising cycle has begun. This is the time it
takes to heat up.
D. Rack
- When the water in the tank (H) reaches the minimum level, the appliance stops heating, the button remains
pressed and the LED light (J) switches off. The appliance is equipped with a device that automatically
switches off the sterilise function.
- Accessories remain sterile for up to 24 hours, provided the lid (B) is not lifted.
- It is recommendable to always place bottles face down in the basket (E) so that the steam can penetrate
F. Basket handle
better, thus making sterilising more effective.
1- Remove the lid (B), rack (D) and basket (E).
2- Check the Steam conveyor (N) is properly fixed on the Electric unit (H), with the arrow on the top of Steam
conveyor facing the ON/OFF button (I)
3- Fill the tank through the electrical unit (H) with cold water. Fill the tank with 40ml of water. Make sure the
amount of water does not exceed the level marked on the appliance. (FIG A)
G. Bottle stands
Replace the basket (E) -if you are going to use it with bottles- and rack (D)- if you are also going to use it with
small accessories-, close the lid (B) and make sure all the parts are correctly fitted. Do not place more bottles
in the steriliser than those recommended by the manufacturer and do not force them once they are inside.
4- Switch on the appliance. The indicator light (J) will not light up yet.
N. Steam conveyor
5- Press the ON/OFF button (I) to start the sterilising cycle. The LED light (J) will now switch on. (FIG B)
6- Once the cycle has finished, the LED light (J) will switch off.
7- Press the ON/OFF button (I) again to completely switch off the appliance.
K. Power supply cable
8- Before removing the lid (B), wait for a few minutes for the steriliser to cool down.
9- Remove accessories carefully using the tongs (M).
L. Base with water tank
Fig A
· WARNiNg:
Hot steam will be released as soon as the lid is opened. Be very careful and keep back a little to avoid scalding.
· RECOmmENDATiONS:
- If you need to use the steriliser again immediately, wait for it to cool down for approximately 60 minutes.
- If the outside of the steriliser becomes wet as a result of filling or emptying the water tank (H), dry them with a
cloth.
EN - 49
Fig B