Safety devices
1.
Vacuuming unit
2.
Limiting valve position (3997 - 3997C series)
3.
Limiting valve position (3997W - 3997WC series)
4.
Limiting valve
Do not tamper any limiting valve setting.
Controls, indicators and connections
1
Vacuum gauge
2
Hour counter
PM
Start button
PA
Stop button
PS1
Filter shaker start button (3997 - 3997W only)
H1
Voltage presence white indicator
H2
Thermal overload red indicator
Q1
Main / door blocking switch
Compressed air low pressure red indicator
H3
(3997C - 3997WC only)
H4
Primary filter clogging blue indicator
GB
C31
Figure 4
WARNING!
Figure 5
Inspection prior to starting
5.
Inlet
Prior to starting, check that:
■
the filters are installed
■
all latches are tightly locked
■
the vacuum hose and tools have been correctly fitted into
the inlet (5)
■
the bag or safety dust container is installed, if applicable.
WARNING!
Do not use the vacuum cleaner if the filter is faulty.
WARNING!
The Mod. "3997W - 3997WC" vacuum cleaner is not
provided with quick-fit coupling of the suction hose,
therefore the hose must be fixed to the Ø120 inlet
hose with a clamp.
Starting up
WARNING!
Lock the castor brakes before starting the vacuum
cleaner (18, Fig. 1).
Starting/stopping the vacuum cleaner
■
Turn the main switch (Q1) from - 0 - (OFF) position to - I
- (ON) position
■
Switch on the vacuum cleaner by pressing the green
start button (PM)
Press the stop button (PA) to stop the vacuum cleaner.
Thus the electric power supply to the motor is cut out.
WARNING!
When the vacuum cleaner is not used, turn the main
switch (Q1) in -0- (OFF) position and disconnect the
plug from the network switch installed on top of the
machine.
8
Figure 1
Figure 5