Troubleshooting Guide - Porter & Cable FR350B Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MANY COMMON PROBLEMS CAN BE SOLVED EASILY BY UTILIZING THE CHART
BELOW. FOR MORE SERIOUS OR PERSISTENT PROBLEMS, CONTACT A PORTER-
CABLE SERVICE CENTER OR CALL 1 888 848-5175.
To reduce the risk of serious personal injury, AlWAyS disconnect
air from tool and engage trigger lock, before all repairs.
SyMpTOM
Air leak near top of
tool or in trigger area
Tool does nothing or
operates sluggishly
Air leak near
bottom of tool
Tool jams frequently
Other
Height (inch/mm)
Width (inch/mm)
length (inch/mm)
Weight (lbs/kg)
Recommended Operating pressure
Air Consumption per 100 cycles
loading capacity

TROUBleSHOOTInG GUIDe

pROBleMS
Loose screws.
Worn or damaged
o-rings or seals.
Inadequate air supply.
Inadequate lubrication.
Worn or damaged
o-rings or seals.
Loose screws.
Worn or damaged
o-rings or bumper.
Incorrect fasteners.
Damaged fasteners.
Bent collation wire.
Canister or nose screws loose Tighten screws.
Canister is dirty.
Driver tip is worn or damaged. Install Driver Maintenance Kit.
TOOl SpeCIFICATIOnS
15 - ENG
SOlUTIOnS
Tighten screws.
Install Overhaul Kit.
Verify adequate air supply.
Put 5 or 7 drops of
oil into air inlet.
Install Overhaul Kit.
Tighten screws.
Install Overhaul Kit.
Verify approved fasteners
of correct size and 22°
collation angle.
Replace with undamaged
fasteners.
Clean magazine.
Contact a PORTER-CABLE
Authorized Warranty
Service Center
FR350B
14.76/375
4.72/120
21.65/550
7.17/3.25
70-120 psi (4.8 to 8.3 bar)
9.74 CFM
60 nails

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido