LEAK TESTING:
To prevent fire or explosion hazard:
•
DO NOT smoke or permit ignition sources in the area while conducting a leak test.
•
Perform test OUTDOORS only in a well ventilated area.
•
Never perform a leak test with a match or open flame.
•
Never perform a leak test while the grill is in use or while grill is still hot.
WHEN TO PERFORM A LEAK TEST:
•
After assembling your grill and before lighting for the first time, even if purchased fully assembled.
•
Every time the LP gas cylinder is refilled or if any of the gas components are replaced.
•
Any time your grill has been moved.
•
At least once per year or if your grill has not been used for more than 60 days.
CHECKING FOR LEAKS:
1. Create a mixture of 50% water and 50% liquid dishwashing soap.
2. Open the lid.
3. Make sure that all burners are off. The red indicator light above the
ON/OFF switch for the burners should not be lit.
4. Turn on the fuel supply at the cylinder valve. Turn the
cylinder valve knob one turn counter-clockwise.
5. Apply the soap water mixture to the following:
A
Supply tank (cylinder) weld.
B
Connection nut to tank valve.
C
Back side of connection nut to brass
nipple.
D
Brass nipple connection into regulator.
E
Front, back and sides of regulator and
connections to gas supply hoses.
F
Hose connection to gas manifold.
G
The full length of gas supply hose.
H
Tank valve to cylinder .
DANGER
WARNING
Watch For Bubbles
F
E
H
G
D
C
B
A
8