Riello Elettronica Cardin GL124EBSS Manual De Instrucciones página 25

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

OPTIONAL INTERFACE SCL
13
12
11
10
9
R_I
G_I
R_E
TX
Legend
SB - shunt box
RX - reception sensor
TX - transmission sensor
L1
- power supply led
DS1 - selection dip-switch
Description :
02
Scheda controllo semaforo/costa Fraba
SCL00
(per GL124 A Mosfet)
10-11-2005
Connecting the optional card "SCL"
• Insert the optional card "A" fig 19.
• Pass the card connection wires through the cable clamp "B" and then
through the opening "C" fig 18.
• Wire up and then insert the terminal blocks into the card "A"
STATUS
Door closed
Pre-flashing stage
Movement stage (opening/closing)
Door stopped but not completely closed
Door completely open (TAI command)
Door completely open (TAE command)
Problem with the optional card
ON
8
7
6
5
4
L1
1 2 3
DS1
G_E
AUX
SB
Connection cable Tx-Rx lenses
wh - white wire
gr
- green wire
br
- brown wire
Scheda aggiuntiva
Once the card has been inserted into the connector "J6" on the
programmer the following functions become available:
1) traffic light control signals;
20
2) interface with the special infrared safety edge;
3) controlling the activation of garage lights or air circulation fans.
The power supply for the indicator lamps and the "AUX"
contact must be drawn from an external source.
If the card is not present or is not being used leave the "Eout" and "CSPF"
parameters set to the value "0" (page 20).
0V SIGN
+12V
The traffic light and CSPF safety edge functions are enabled/disabled
separately one from the other.
The settings for the AUX output must be set directly on the SCL card
using the dedicated dip switches.
3
2
1
wh
Terminal board description
gr
br
1
+12 Vdc power supply output for the special safety edge (max. 60 mA).
2
Signal input from the special safety edge.
0 Vdc power supply for the special safety edge.
3
4-5
Potential free contact NO powering the fan/garage lights (230 Vac 5A)
6-7
Potential free contact NO powering the green external traffic light
signal (230 Vac 5A)
8-9
Potential free contact NO powering the red external traffic light
signal (230 Vac 5A)
10-11 Potential free contact NO powering the green internal traffic light
RX
signal (230 Vac 5A)
12-13 Potential free contact NO powering the red internal traffic light
signal (230 Vac 5A)
Description dip-switch DS1
DIP1
ON: enables management of the special safety edge
OFF: disables management of the special safety edge (the security
device is always deemed to be at rest)
DIP2
ON: the AUX contact remains closed until the door is completely shut
OFF: the AUX contact is only activated once (for the time selected
in DIP3) each time the command TAI / TAE activates the door
DIP3
Only with DIP2=OFF:
ON: activates the AUX output for 30 seconds
OFF: activates the AUX output for 3 seconds
Traffic light signal control
Green and red traffic light signals can be wired to the terminal board
(maximum of 4 lights); the power supply for the lights must be supplied
externally as the terminal board is only fitted with potential free switch
contacts. The function modes with their relative signals are laid out in the
table at the bottom of the page.
21
Controlling the safety edge
The safety edge has two sensors (each with a protruding three-wire cable)
fitted into the rubber profile. These wires should be connected in parallel
by joining the wires with the same colour and then connecting them to the
terminal board as follows:
terminal board 1 brown wires (power supply +12 Vdc)
terminal board 2 green wires (signal)
terminal board 3 white wires (power supply 0 Vdc)
The safety edge is recognised by moving DIP1 to the "ON" position.
To economise on battery power during blackouts, power will not be routed
to the safety edge unless the door is moving.
The "safety test" is never carried out for this device.
22
Alarm indications
No ulterior indications will be given if there is a problem with the optional
SCL card as the display on the programmer will allow you to verify
the status of the individual safety devices.
Contact R_I
open
intermittent
closed
closed
open
closed
closed
25
Contact G_I
Contact R_E
open
open
open
intermittent
open
closed
open
closed
closed
closed
open
open
open
closed
Contact G_E
open
open
open
open
open
closed
open

Publicidad