8.
Wipe off residual water from the opening area of the Blue Connect and inside the hole with
the cloth.
9.
Take the new probe, scan its QR code and remove the protective cap. Be careful not to drop
the probe as it is a very fragile item.
10.
Wipe the black plastic body of the new probe if needed. It should be perfectly dry.
NB: Make sure the gold contacts on the top of the probe are clean (shiny) and dry.
Otherwise, clean them with a cotton swab soaked in household alcohol.
11.
Place the new seal supplied with the replacement on the new probe.
12.
Insert the probe and turn it until it is placed correctly. Three beeps are emitted within 15
seconds.
13.
Using the screwdriver, screw the screw (all the way but without forcing) on the edge of the nut.
13