4. Press the Test Button and twist the
motor shaft in the desired direction of
rotation.
• If the CORRECT LED is lit, the
connections have been correctly
identified. Disconnect the test
instrument from the motor.
• If the INCORRECT LED is lit, switch
any two leads and repeat Step 4.
Note: The motor rotation function
Maintenance
Keep the test instrument clean and dry.
Replace leads that are worn or damaged.
Do not attempt to repair this test instrument.
It contains no user-serviceable parts.
Battery Testing and Replacement
If the green Test LED does not illuminate
brightly when the Test Button is pressed,
replace the battery:
1. Disconnect the test instrument from
the motor.
2. Gently pry the back cover off with a
screwdriver.
3. Install a new battery and replace the cover.
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070
relies on the residual magnetism
of the motor to indicate the
direction of motor rotation. If the
motor was not operated by the
manufacturer prior to shipment,
it will not have residual
magnetism and the 5123 will not
indicate the direction of motor
rotation.