Ribind JOLLY ONE Manual De Instrucciones página 20

Ocultar thumbs Ver también para JOLLY ONE:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

G
B
TECHNICAL DATA / INSTALLATION JOLLY ONE
TECHNICAL DATA
Max gate weight
Max gate surface
Limit switch winding capacity
Nominal functioning torque
Max operating torque
Max lifting force from earth
Max operating force
Pulley revolutions
Pulley diameter
Shaft diameter
EEC Power supply
Motor capacity with load
Power absorbed with load
Capacitor
Functioning cycles
Daily operations suggested
Service
Nominal functioning time
Motor weight
Working Temperature
Protection
ROLLING GATE CONTROL
The European Standard EN 12604 "Industrial, Commercial and Garage Doors and Gates -
Mechanical Aspects - Requirements", at the point 4.3. "Protection against unintentional and
uncontrolled movements" requires also that*:
a - The vertically operating door leaves shall be balanced so that the door leaf can stop
in any position, or that the out-of-balance state shall not produce, in any case, a
static force at the primary closing edge of the door exceeding 150N (15,3 kg / 33,70
lbs). Verify it after having manually released JOLLY ONE operator.
b - If a spring fails, the resulting out-of-balance static force occurring at the primary
closing edge of the roller shutter shall not exceed 200N (20,4 kg / 44,94 lbs),
even when JOLLY ONE operator is manually released. After this failure, you must
intervene on the door to substitute the broken spring and correct the balance state.
Therefore, we suggest you to fraction the roller shutter weight with an adequate
number of springs (*This is a free interpretation).
WARNING: The EN 12445 standard ´Industrial, commercial and garage doors and gates
- safety in use of power operated doors - test methods´ at point 4.1.2 ´safeguarding
against hazard of being lifted´ provides that the rolling gate shall not be able to lift
more than 20 kg/44lbs.
In order to meet this standard, RIB suggests to install the control board with electric
power regulation J-CRX (cod. ABJ7080).
kg/lbs
2
m
N. rotat.
Nm
Nm
kg/lbs
kg/lbs
rpm
mm/in
mm/in
60/2,3 - 42/1,64 with adapter ACJ9040 - 48/1,9 with adapter ACJ9050
W
570 (50Hz) - 550 (60Hz)
A
µF
N.
N.
s
kg/lbs
°C
IP
371 / 14,6
Measurements in mm/in
JOLLY ONE
220/485
16
8,5
150
110
150/330
110/242
10,4 (50Hz) - 13,4 (60Hz)
200/7,9 - 220/8,67 with adapter ACJ9055
230V ~ 50-60Hz
2,7 (50Hz) - 2,6 (60Hz)
20
5 - 20s/2s
20
30%
240
9,5
-10 ÷ +55
30
Parts to install meeting the EN 12453 standard
Skilled persons
COMMAND TYPE
(out of public
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote control device)
automatic
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2012.
B: Key selector with manned operation, like code ACG1010.
C: Motor force regulation.
D: Safety edges or Sensor able to detect an obstacle and/or other safety devices to
keep thrust force within the limits of EN12453 regulation - Appendix A.
E: Photoelectric cells, eg. code ACG8026 (To apply on the whole height of the door up
to max 2,5 m as indicated on EN 12445 point 7.3.2.2).
I
N ORDER TO ENSURE A CORRECT FUNCTION ONLY RIB'S
COMPONENTS MUST BE USED
1 - JOLLY ONE operator
2 - Photoelectric cells (external)
3 - Push-Button
20
120V ~ 60Hz
460
4,2
60
420
USE OF THE SHUTTER
Skilled persons
(public area)
area*)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
4 - Key selector
5 - Tuned aerial
6 - Flashing lamp
Unrestricted use
-
C and D, or E
C and D, or E
C and D, or E

Publicidad

Tabla de contenido
loading

Tabla de contenido