(see page 8).
To Fill The Gun with a Filler Pump
1. Engage the follower rod with the follower by
rotating the follower handle.
2. Insert the gun vent/bulk fill valve into the filler
pump socket (see Fig. 7).
3. Operate the filler pump to fill the container.
When the follower rod groove is exposed,
the grease tube assembly is filled. The fol-
lower rod will be extended approximately 8
inches (20 cm). Do not overfill!
4. Disengage the follower rod from the follower
by rotating the follower handle. Push the
follower rod into the grease tube assembly.
Remove Air Pocket! Air pocket at grease
inlet will prevent grease from being pumped.
Unscrew the vent valve three to four turns to
remove small air pockets trapped in this area.
If the air pocket is substantial and no grease
flows from coupler after trigger is pulled for 15
seconds, see following steps.
5. Reset display reading after purging air.
To Expel Air Pockets (Air Purging)
1.
Withdraw the follower rod from the grease tube
assembly cap and engage it with the follower by
rotating the follower handle.
2.
Unscrew the plug of vent valve 3-4 turns. Exert
force on the follower handle until grease flows
through the small hole in the side of the vent
valve.
3.
Tighten the vent valve.
4.
Pull the trigger in short bursts to operate gun
until trapped air is expelled. Disengage the
follower rod from the follower by rotating the
follower handle. Push the follower rod into the
grease tube assembly.
5.
If step 2 fails, unscrew the grease tube assem-
bly 3 turns from the pump assembly.
6.
Exert force on the follower handle until lubricant
oozes from the grease tube assembly and
pump assembly interface.
7.
Retighten grease tube into the pump assembly.
Disengage the follower rod from the follower by
rotating the follower handle. Push the follower
Form 404264
Models 1860, 1862, 1862E, 1864
PowerLuber Grease Gun (Lithium)
Figure 7
rod into the grease tube assembly.
CHARGER OPERATION
CHARGING THE BATTERY PACK
Before using your PowerLuber for the first time,
the battery pack should be fully charged. If the
battery pack is installed in the PowerLuber,
remove it and follow "Charging Procedure"
below.
Lincoln chargers are designed to charge
Lincoln Lithium batteries in 30-60 minutes
depending on the battery's state of charge and
temperature.
CHARGING PROCEDURE
Make sure power circuit voltage is the same
as that shown on the charger specification
plate.
1. Plug the charger into an appropriate outlet
before inserting battery pack.
2. Insert the battery pack into the charger. The
green (charging) light will blink continuously
indicating that the charging process has
started.
3. The completion of charge will be indicated
by the green light remaining ON continu-
ously. The pack is fully charged and may be
used at this time.
4. Disconnect charger from power source
120/230 volts present at charging terminals. Do
not probe with conductive objects. Danger of
electric shock or electrocution.
when not in use.
Page Number - 9