CAUTION
If the heat exchanger is not used during winter months it must be drained
to prevent frost damage.
NOTE: For Winterising / maintenance - it is recommended that the heat
exchanger is installed with isolation valves on both water input and out-
put sides of the primary and secondary circuits. This will allow the water to
be shut off on both sides and aid removal from the system, when
required.

Water quality

To prevent damage to your heat exchanger, the water quality must be kept
within the following limits:
Chlorine Content: Max 3mg/l (ppm)
Chloride Content: Max 150mg/l
PH: 6.8-8.0
Calcium Hardness: 200-1000mg/l (ppm)
RoHS compliance statement
Elecro Engineering Limited certify that our Electric Swimming Pool Heater
Range/Heat Exchanger Range complies in accordance with RoHS Directive
2011/65/EU on the restriction of hazardous substances.