6.1.2 Servicing the stove
This must be done at least once a year, or whenever
the stove itself displays the maintenance required
message.
The technician must:
-
thoroughly clean the fumes circuit
-
check the condition and tightness of all seals
-
check the condition and cleanliness of all
internal components
-
check the tightness and cleanliness of the
-
remove all pellet residue remaining in the pellet
tank
-
check that the stove is operating properly
-
reset any warnings and alarms.
ACCESS TO SMOKE EXTRACTION FAN
In case of maintenance, you can access the
raise the top inspection grill
unscrew the two screws that secure the
protection grill and remove it from its seating
if necessary, unscrew the screws that secure
the protection cap and remove it from its
seating.
ACCESS TO THE WATER CIRCUIT
Remove the left side, loosening the screws on the
Remove the left front cover by loosening the two
screws on the left side and the other two on the
door closing. (Fig. 6.2 b).