4_
the bar should start to close.
Note: if it opens, stop the programming procedure by resetting the electric panel (discon-
nect the power supply to the panel for at least 5 sec. and set dip-switch no. 8 to OFF); with
the control panel disconnected, exchange the motor supply wires. Restart the procedure
from point 1.
5_ when the gate has closed, after approximately 2 seconds a complete opening manoeuvre is
executed automatically;
6_ when the gate has opened, set dip-switch no. 8 to OFF;
7_ the automation is now ready for operation.
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are oper-
ated, a complete manoeuvre must be carried out in order for the new settings to take effect.
LOGIC ADJUSTMENTS
TRIMMER
RALL.
slowdown distance adjustment: from about 10 to 100 cm;
T.C.A.
Automatic Closing time adjustment: from about 0 to 25 seconds (see dip-
switch no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gear-
motor to obstacles diminishes and therefore the thrust force increases; vice-
versa, by rotating it counter-clockwise, the sensitivity of the gearmotor to
obstacles increases and therefore the thrust force diminishes.
Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
SLOW DOWN
3
SETUP
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
BAR
7
SETUP
8
MEMO
16
when completely open, closure is automatic after the set time on the
On
T.C.A. trimmer has past;
Off
the closing manoeuvre requires a manual command;
when the automation is operating, a sequence of opening/closing
On
commands causes the bar to OPEN-CLOSE-OPEN-CLOSE, etc.
in the same conditions, the same sequence of commands causes the
Off
bar to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by step
function) (see also dip switch
On
slowdown setting for CITY/M and CITY/O barrier;
Off
slowdown setting for CITY/V, RBL4 and RBLO barrier;
On
the bar responds as established by dip switch No. 2
Off
the bar ignores the closure command during opening;
On
the pre-flashing function is enabled;
Off
the pre-flashing function is disabled;
On
the "photocell test" function is enabled;
the "photocell test" function is disabled. N.B.: to be used when the
Off
photocells are not used;
On
set for CITY/V, RBL4 and RBLO;
Off
set for CITY/M and CITY/O;
On
the memorization function is enabled for self-learning of the travel;
leave the dip-switch in this position when the memorization proce-
Off
dure has been completed.