Connecting The Unit; Guarantee - Astralpool EASYWATCH 32460 Manual De Instalación Y De Usuario

Equipo de control y regulación para piscinas residenciales
Ocultar thumbs Ver también para EASYWATCH 32460:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
EASYWATCH

2 CONNECTING THE UNIT

MAINS SUPPLY
(connections 1, 2 and 3). The unit operates with
alternating voltage of 230Vac 50Hz.
DISPENSER PUMPS
(connections 4, 5 and 6 for the pH and 7, 8 and 9
for the RedOx potential). Power supply of the
pumps must be 230 Vac 50Hz, and a maximum of
1Amp per pump.
FLOW DETECTOR
(connections 24 and 25 FLOW). By connecting a
voltage-free contact of the motor contactor, we can
monitor the circulation of water through the probe fit-
ting circuit. Operation will always be in closed circuit.
A flux meter (33314) can be installed as an option.
TEMPERATURE PROBE
PTC-1000 (optional 33134).
ALARM
(connections 10, 11 and 12) Voltage-free switched
relay that activates when an anomaly occurs, trig-
gering the alarm. It will disconnect once the ano-
maly, which triggered the alarm, has been correc-
ted or when the Info. key is pressed.
EASYWATCH
Connecting the pH/RedOx Motherboard
Alarm
Pump
RedOx pump or
pH
electrovalve
5
CONTROL AND ADJUSTMENT UNIT FOR
RESIDENTIAL SWIMMING POOLS 32460
Imputs
RS232
Access
Alarm
Relay
TO THE POOL
RECIRCULACIÓN
PUMP
ENGLISH
ELECTRODES
The reading electrodes are connected in differen-
tial mode and therefore the connection of the equi-
potential input is essential between the probe fitting
and the unit. The unit is supplied with the connec-
tion wires of the electrodes and the equipotential
input connected as indicated in the diagram.
To install the electrodes, proceed as follows:
EASYWATCH
Connecting the pH/RedOx Probe Boards
Temp. probe
(NTC)
pH
electrode

3 GUARANTEE

Guarantee of 24 months excluding parts which
normally wear or perishable parts such as pH and
RedOx (mV) potential electrodes.
The improper use of the unit will terminate the gua-
rantee. The guarantee does not cover damage
caused by improper handling, unsuitable repairs,
modifications, unsuitable transport, knocks and
falls, accidents caused by weather, etc.
EASYWATCH-32460
INSTALLATION
MANUAL
Equipotential
RedOx POT
electrode

Publicidad

Tabla de contenido
loading

Tabla de contenido