Power Up UTILIDRAIN (8 kHz)
1
8kHz
1. Remove the end cap and insert the battery.
2. Screw the end cap back on.
3. The LED will fl ash indicating the sonde is
active.
UTILIDRAIN: Depth Reading
1. Position UTILIFINDER +
directly over and in
line with UTILIDRAIN
2. Ensure UTILIFINDER +
is set to 8 kHz.
3. Press and release
"i-button" for depth
reading.
8 kHz
Leica UTILIFINDER + User Manual
2
GHOST
SIGNAL
When active, UTILIDRAIN produces
a peak signal over its body and a
ghost signal either side.
2
PEAK SIGNAL
GHOST
SIGNAL
1
3
metres
UTILIDRAIN Search
1. Set UTILIFINDER + to 8 kHz mode
and walk in line with the suspected
direction of UTILIDRAIN observing the
display.
2. Retrace your steps and position the
UTILIFINDER + over the peak signal.
Move the UTILIFINDER + left and right
until the highest numeric reading is
obtained.
3. The highest numeric reading will indi-
cate the peak signal and position of
UTILIDRAIN.