Required Tools; Installation - GF 582 Manual De Instrucciones

Ocultar thumbs Ver también para 582:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Instruction manual

8 Required tools

Tool
Allen wrench
Open-end wrench
Hook wrench or strap wrench
Screw driver
Fixing unit, e.g. jaw vice

9 Installation

WARNING – ONLY FOR MANOMETER VERSION
Danger of material damage and/or injury due to changes of the manometer!
Valid for versions with and without adaptor.
 The manometer is installed, preset and checked at the factory. Therefore,
ensure that no changes are made at the manometer.
The valve bodies are suited for various connection types:
Connection: radial installation and removal
Pressure reducing valves type 582/pressure retaining valves type 586 are supplied
with released spring.
DN 10/15
DN 20/25
AF 6
AF 8
AF 19
AF 24
80 - 90 mm
95 - 100 mm
Connection: spigot ends
DN 32/40/50
AF 10
AF 30
135 - 145 mm
Size 1
no difference
Required tools
33

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

586

Tabla de contenido