Instruction
Instruction
Manual
Manual
CL3100
ENGLISH
• BacKLIGHt
• WorKLIGHt
• MaX / MIN
• aUto FUNctIoN
SELEct
• 3-3/4 DIGIt
3999 coUNt LcD
www.kleintools.com
ENGLISH
CL3100
Instruction Manual
GENEraL SPEcIFIcatIoNS
The Klein Tools CL3100 is an auto-function selecting hook meter.
It measures AC / DC voltage, AC current, and resistance. It can also test
continuity.
•
operating altitude:
2000 meters
•
relative Humidity:
75% max
•
operating temperature:
0°C / 32°F to 40°C / 104°F
•
Storage temperature:
-10°C / 0°F to 50°C / 122°F
•
accuracy temperature:
18°C / 64°F to 28°C / 82°F
•
0.1*(specified accuracy) / °C
temperature coefficient:
•
Sampling Frequency:
2.5 samples per second
•
0.5"
Jaw Size:
•
Dimensions:
10.25" x 2.5" x 1.5"
•
8.6oz.
Weight:
•
calibration:
Accurate for one year
•
CAT III 1000V, CAT IV 600V
cat rating:
•
accuracy:
± (% of reading + # of least significant digits)
WarNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring
a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the category based
rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual protective
equipment to prevent shock and arc blast injury where hazardous live
conductors are exposed.
SYMBoLS
~
ac alternating current
Dc/ac Voltage or current
Dc Direct current
Safe for disconnect
from live conductors
Warning or caution
Double Insulated class II
Ground
ac Source