Electrical Specifications - Klein Tools CL3100 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
current: < 200a ac
2.
correct
3.
resistance / continuity
PRESS
V/A
Continuity
0
10
20
30
40
resistance: < 40MΩ
SYMBoLS USED oN LcD
~
ac Measurement
-
Negative Dc Value
Maximum reading
MAX
AT
auto range active
overload: range
O.L.
Exceeded
V
Voltage Measurement
Ω
resistance in ohms
m
Milli 10
-3
M
Mega 10
6
Incorrect:
Opposing currents cancel
Continuity
0
10
20
30
40
continuity: tone below 30Ω
Dc Measurement
Low Battery
Minimum reading
MIN
auto Function
AUTO
active (V/a)
Apo
auto Power-off active
A
current in amps
continuity test
k
Kilo 10
3

ELEctrIcaL SPEcIFIcatIoNS

Dc Voltage Measurement
range
resolution
2.1 ~ 1000V
0.001V ~ 1V
-1.8 ~ -1000V
0.001V ~ 1V
1000V
overload Protection:
>
10M Ω
Input Impedance:
ac Voltage Measurement
range
resolution
1.3 ~ 750V
0.001V ~ 1V
overload Protection:
750V RMS
Frequency:
45 to 400Hz
10M Ω
Input Impedance:
response:
Averaging
ac current Measurement
range
resolution
0.9 ~ 200A
0.1A
overload Protection:
200A
45 to 400Hz
Frequency:
Averaging
response:
resistance Measurement
range
resolution
400Ω
0.1Ω
4kΩ
0.001kΩ
40kΩ
0.01kΩ
400kΩ
0.1kΩ
4MΩ
0.001MΩ
40MΩ
0.01MΩ
overload Protection:
600V
continuity test
overload Protection
600V
accuracy
± (1.0% + 4 digits)
accuracy
± (1.5% + 3 digits)
accuracy
± (2.5% + 8 digits)
accuracy
± (1.0% + 4 digits)
± (2.0% + 4 digits)
open circuit Voltage
Appx. 0.45V

Publicidad

Tabla de contenido
loading

Tabla de contenido