EN: Installation Sheet
Introduction
The VE1012 series consists of models VE1012 and
VE1012AM. These detectors use PIR or PIR-AM sensors.
They have a patented mirror, pyro, and signal processing
technology.
Installation guidelines
The technology used in these detectors resists false alarm
hazards. However, avoid potential causes of instability such as
(see Figure 1):
•
Direct sunlight on the detector
•
Strong draughts onto the detector
•
Heat sources within the detector field of view
•
Large animals within the detector field of view
•
Obscuring the detector field of view with large objects,
such as furniture
•
Objects within 50 cm (20 in.) of the anti-masking (AM)
detector
•
Installing two detectors facing each other and less than
50 cm (20 in.) apart
P/N 146414999-2 • REV 2.0 • ISS 20JUL10
J3 J4
J3 J4
J3 J4
CP
Normal
4.7 k
Ω
A
larm
9.4
kΩ
Tamper
Short
0
Ω
VE1012AM
J3 J4
CP
VE1012AM
J3 J4
CP
Normal
4.7 k
Ω
A
larm
9.4
kΩ
Tamper
Short
0
Ω
AM/TF
Installing the detector
Figure 7 legend
Item
Description
1.
Standard connection (factory default)
2.
Dual loop connection
CP
Control panel
WT
Walk test
AM
Antimasking
D/N
Day/night
Rtest
Remote test
To install the detector:
1.
Lift off the custom insert and remove the screw
(see Figure 2, step 1).
2.
Using a screwdriver, carefully prise open the detector (see
Figure 2, steps 2 and 3).
3.
Fix the base to the wall between 1.8 m and 3.0 m (5.9 and
9.8 ft.) from the floor. For flat mounting use a minimum of
two screws (DIN 7998) in positions A. For corner-mounting
use screws in positions B or C (Figure 4). To install a pry-
off tamper, use position A or B.