Trouble shooting
Problem
Filter cleaning does not
function. (Not S 11000E)
Vacuum producer runs but
no suction.
Vacuum producer runs but
poor suction.
Machine blows dust.
Fault
Compressed air supply
broken.
Electric supply broken.
Wrong voltage connec-
ted.
The tubing between the
fi lter unit and vacuum
producer not connected.
Plugged tubing or hoses.
There is no plastic sack
or container attached to
the fi lter unit.
The plastic sack or con-
tainer not fi rmly attached
to the bottom of the fi lter
unit.
Pump rotation back-
wards.
Hole in hoses or untight
tubing.
Plugged fi lters.
Filter is perforated or
has come loose.
S 11000, S 11000X, S 11000E - 19
Solution
Check hoses, connections
and compressor.
Check solenoid valve, ca-
bles, connections, fusing
and transformer.
Check the voltage
(should be 24 V AC).
Connect the tubing.
Check and clean these.
Connect a plastic sack or a
container.
Secure the plastic sack or
the container.
Electrician should change
phases.
Check this.
Clean or change fi lters (see
'Filterchange').
Check the fi lters and change if
necessary.
Part No 9057