Indicator Light; De-Activation After Use - mcmurdo FAST FIND 200 Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

32223 fstfnd manual 120x120transq740PG:Layout 1

INDICATOR LIGHT

The indicator light will start flashing
immediately the Fast Find is activated
FAST FIND 200 Light indication
PLB ACTIVE
1 flash every 3 seconds
SATELLITE TRANSMISSION OK
Large flash once every 50 seconds
FAST FIND 210 WITH GPS Light indication
GPS SEARCHING
2 flashes every 1 second
SATELLITE TRANSMISSION SENT WITH
GPS LOCATION OK
Sequence repeats every 50 seconds
PLB ACTIVE
1 flash every 3 seconds
3/2/09
15:44
Page 9
FLASH SOS FEATURE
When the PLB is active, pressing the ON
button will cause the indicator light to flash a
Morse code SOS pattern. This can be used to
attract attention after nightfall. The SOS
pattern is repeated four times on each press.
To conserve battery life a maximum of
30 presses are allowed, after which this
feature is disabled.

DE-ACTIVATION AFTER USE

To turn off the Fast Find, press and hold the
TEST button for several seconds until the
indicator light stops flashing.
We recommend the antenna is re-wound
under the plastic peg. If possible, the yellow
antenna cover should
be pushed back in
place and temporarily
taped over, to avoid
accidentally pressing
of the ON button.
Important
As soon as possible the PLB should be
returned to a service agent, who will fit a new
antenna cover and check the battery
condition. If the PLB was active for more than
a few hours we recommend fitting a fresh
battery to ensure the full 24 hour operational
life is still available.
SELF TEST
Self-test verifies operation of the PLB by
checking all key features including the battery
and alert transmitters.
TEST button
Push and hold the
SELF TEST button for
a minimum of 2
seconds, the
FAST FIND
GET FOUND WITH
indicator light will flash once to indicate the
start of the self test sequence.
After a few seconds, a good self-test will
result in the indicator light flashing a number
of times in quick succession depending on
battery usage;
fresh battery self test pass
minimum usage self test pass
medium usage self test pass
NO FLASH
self test fail PLB requires service
The PLB will switch off automatically when
the self-test has completed.
Important
Each self-test draws small amounts of energy
from the battery pack. Unnecessary testing of
the PLB will reduce the run time of the PLB in
an emergency. On average, the PLB should
only be self tested 12 times per year, or a total
of 60 times during the 5 year battery lifetime.
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fast find 210

Tabla de contenido