- GB -
Installation and connection
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
• Isolate the unit before starting any work.
• Secure the unit to prevent unintentional switching on.
Attention! Dangerous electrical voltage.
Possible consequences: Death or serious injuries due to operation of this unit in a swimming pond.
Protective measures:
• Do NOT use this unit in a swimming pond.
• Adhere to national and regional regulations.
Operating the unit in the pond
C
• Never operate the pump in a swimming pond.
• Only operate the pump when it is below the water surface level.
• Only operate the pump with the filter basket fitted.
• Ensure that the pump is in a secure and stable position.
• The position of the pump outlet can be changed. The pump casing has to be turned to achieve a different position.
(→ Turning the pump casing)
How to proceed:
D
1. Screw the stepped hose adapter including union nut and sealing ring to the outlet.
2. Connect the hose with the stepped hose adapter and secure with a hose clip.
Install the unit at a dry place
E
• Swimming pond or pool that may be accessed by people.
– Install the unit at least 2 m away from the water.
• Do not expose the unit to direct sunlight.
• Ensure that the pump is in a secure and stable position.
• The position of the pump outlet can be changed. The pump casing has to be turned to achieve a different position.
(→ Turning the pump casing)
How to proceed:
F
1. Remove the screws for fastening the filter basket and remove the filter basket.
2. Screw the hose connector with union nut and seal onto the inlet.
3. Connect the hose with the stepped hose adapter and secure with a hose clip.
4. Screw the hose connector with union nut and seal onto the outlet.
5. Connect the hose with the stepped hose adapter and secure with a hose clip.
6. Fasten the pump to a suitable base using screws (not included in the scope of delivery).
Note!
Recommendations for hoses and pipes:
• Use 50 mm (2 ") hose connectors and hoses for a length of up to 5 m.
• Use DN 75 or DN 100 pipes for a length greater than 5 m.
16