5.
TECHNICAL SPECIFICATIONS
5.1
SENSOR AND DISPLAY
t kN daN lbs ton kg
F
STOP MAX
E
D
GB
A
Units used
B
Tare
C
Batteries low
D
Peak Hold
E
Auto stop
F
Signed measurement
MODEL
Maximum capacity
Test load
Safety coefficient
Precision
Increment
Max. Display
Number height
Autonomy
Weight
IP Protection
Usafe
Sensitivity to T°
Sensor material
Dimensions mm
Radio option
TARE
B
+ –
C
Indicators
LLX1
LLX1
0.5 t
1 t
t
0.5
t
0.75
1.5
±
1
daN
daN
0.2
0.5
daN
mm
kg
1.1
1.1
A
220
220
B
196
196
C
14
14
D
90
90
E
32
32
F
16
16
G
47.5
47.5
H
45
45
RF technology: Zigbee 2.4 GHz
A
LLX1
LLX1
2 t
3.2 t
1
2
3.2
3
4.8
Minimum 4
0.2 % FS
2
4
6
1
1
110 % maximum capacity
450 h (Batteries 1.5 V "AA ")
1.3
1.5
I.P. 65
From - 20° to 40°C
0.05% per 10°C
Aluminium
233
243
207
207
22
22
100
100
32
32
24
24
47.5
47.5
50
50
Range : 40 m in free field, see details § 14
6
T
LLX1
LLX1
LLX1
5 t
6.3 t
12.5 t
5
6.3
12.5
7,5
9.6
18.75
10
13
2
2
18
2.3
2.3
275
275
343
217
217
257
28
28
115
115
125
32
32
29
29
47.5
47.5
66.5
57
57
LLX1
20 t
20
30
25
40
5
10
4.3
7
371
269
42
54
134
51
67
48
64
67
62
66