GB
00
cancella
reset parametri
cancella 1 radiocomando
cancel l a tutta memori a radi o
ttca
•
= automatic closing time
t m1
•
= motor working time
aped
•
= pedestrian opening
rlap
•
= slowed stroke in opening
rlch
•
= slowed stroke in closing
senc
•
= encoder sensitivity
fm1a
•
= motor power in opening
fm1c
•
= motor power in closing
brak
•
= braking current
trel
•
= N.O. output activation time
tdec
•
= deceleration time
da
•
= opening direction
ca
•
= automatic closing
ba
•
= blocks impulses during opening
bp
•
= blocks impulses during pause
cr
•
= rapid closing
2p
•
= open/close operation
pl
•
= prefl ashing
sv
•
= suction lock
re
•
= energy saving
fcm
•
= magnetic limit stop
en
•
= encoder operation
ss
•
= soft start
oc
•
= open/close operation
it
•
= itotal inversion after meeting an obstacle
2b
•
= two safety ribs
cf
•
= operation of the fi xed code receiver
al
•
= alarm
reset parametri
•
cancella 1 radiocomando
•
cancella tutta memoria radio
•
apprendimento
•
leggi codice
•
23
00
•
= instant power absorbed by the motor
WARNING: For the navigation diagram of the English menu,
see the instructions in the other languages.
= setting of factory parameters
= cancels one transmitter
= learning the stroke
= to identify and recognise transmitters
lingua
italiano
english
= cancel all registered transmitters
apprendimento
leggi codice