Troubleshooting (cont'd)
Symptom*
Distortion, dialing
difficulty
Dead circuit
* Wet cables may cause most of these symptoms and may cause multiple symptoms to appear
at the same time.
14
Possible Cause /
Troubleshooting Step
(1) When using the
test set in Talk
mode, the voltage
will be lower than
normal.
(2a) When using the
test set in Monitor
mode, or with the
test set discon-
nected, the voltage
will be normal.
(2b) When using the
test set in Monitor
mode, or with the
test set discon-
nected, the voltage
will be lower than
normal.
Open circuit or
short circuit
Explanation
(2a) This indicates a high-resistance fault,
which restricts the amount of current
flowing through the circuit. Possible faults
include a poor connection, wet cables, or a
line extender failure.
(2b) This indicates a partial short circuit.
Break the circuit down into sections and check
each section for continuity.