specific version with indicator for absence of sync:
same protocol as the table above, but when the clock has not received the
right sync code yet, or when the sync signal disappears during more than
24hours, the field "DAY" indicates 3 symbols « ### ».
the 2nd part of 12 extra octets is not generated in this version.

2.2.3. Date / time alternation option (only LEDI)

the clock can be set to display time and date alternating.
The display period for time or date is configurable from 0 to 15 seconds (0 to do not
display)
Date/ time change is also available on double face (LEDi REVERsO)

2.2.4. temperature option

the clock can be set to display time and date alternating.
The display period for time or date is configurable from 0 to 15 seconds (0 to do not
display)
Offset setting available for temperature
Measurement range -15°C ► +65°C accuracy +/-0.4°C
air and water temperature available by probe
the clock can display several zones of temperature through a wire probe or/and
wireless (only LEDi POOL)
wired version :
temperature through probe Pt1000 delivered with 4m cable.
wireless version:
Pt1000 + 4m cable delivered with a radio transmitter (869 mhz)
transmitter powered by 230VaC for a maximum distance of 1000m of transmission
(the distance can be reduced by impediments between transmitter and sensors)