Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 53

Specifications

Display:
Bargraph:
Range selection:
Auto power-off:
Overload display:
Measuring rate:
Clamp opening:
Overvoltage category:
Pollution degree:
Height above MSL.:
Battery display:
Power supply:
Current consumption:
Operation temperature:
Storage temperature:
Humidity:
Dimension:
Weight:
Current AC
Range
0 – 40 mA
0 – 400 mA
0 – 4 A
0 – 40 A
0 – 50 A
50 – 60 A
Voltage AC
Range
0...400 V
Resistance
Range
400 Ω
Continuity
Range
Ω / R
Overload Protection 600 V AC
(at 23 °C ± 5 °C, max. 75% rel. humidity)
3
40 segments
manual
approx. 15 min.
30 measurements/sec. (Bargraph)
3 measurements/sec. (LCD)
ca. 30 mm
CAT II, 600 V
2
up to 2000 m
at low battery
2 x 1,5 V IEC LR6 (alkaline) batteries
approx. 10 mA
-10 °C ... 50 °C (14 °F ... 122 °F)
-20 °C ... 60 °C (-4 °F ... 140 °F)
< 75% relative humidity
183 x 63.6 x 35.6 mm (7.2 x 2.5 x 1.4 in)
0.44 lb (7 oz)
Accuracy
Resolution
50 Hz/60 Hz
10 µA
100 µA
1 mA
10 mA
0,1 A
0,1 A
Accuracy
Resolution
50 Hz/60 Hz
0,1 Ω
Resolution
0,1 Ω
Resolution
0,1 Ω
, LCD incl. functions and symbols
/4
3
±(1,5 % rdg. +3 D)
±(1,5 % rdg. +5 D)
±(3,0 % rdg. +5 D)
±(1,0 % rdg. +3 D)
Accuracy
±(1 % rdg. +3 D)
Beep
ON ≤ 10 Ω; OFF > 38 Ω
12
40 Hz ... 1 kHz
±(2,0 % rdg. +5 D)
±(2,0 % rdg. +5 D)
±(3,5 % rdg. +5 D)
40 Hz ... 1 kHz
±(2,0 % rdg.± 4 D)
Overload Protection
600 V AC
Open Circuit Voltage
< 0,4 V