Requirement for UK
"The Jotul F 370 Advance stoves have been recommended as
suitable for use in smoke control areas when burning wood logs
and when fi tted with a mechanical stop to prevent secondary
air control closure beyond the 382mm 2 and the tertiary air
control closure beyond the 402 mm 2 open positions." Note! In
order to achieve this see the instructions in fi g. 15.
Fig. 15
5. Use the screw (A) and the washer (B) from the bag of
screws and screw it onto the burnchamber.
Fig. 16
•
Use the screws from the bag of screws to attach the
pedestal to the burn chamber in the front. In the rear use
two of the screws from the brackets (fi g. 5 A).
•
Stand the product up.
B
A
4.5 Assembly with an external air
supply (optional extra)
Jøtul F 373 - rear outlet
Fig. 17
Jøtul F 373 - outside air connection
through the fl oor
If the Jøtul F 373 Advance is to be installed with an external air
supply through the fl oor, the outside air inlet (A) must fi rst be
rotated.
Fig. 18
B
C
1. Unscrew the screws (C). Rotate the outside air cover so
that the opening is positioned in the middle.
ENGLISH
External
air supply
C
A
15