4.4 - Setting the gate

Programming work time from 1 sec to 3 min.
The control box is supplied with a work time of 3 min.
Work time setting:
1) Make sure the GATE/ROLLING SHUTTER is CLOSED.
2) Press 2 times the SELECTION key. The W.T led is now flashing.
3) Press the MODE key: the automation start to OPEN and continue
to open until the MODE key is released. It is at this point that the
WORK TIME is memorised.
4) The W.T LED flashes for a few seconds and the gate re-closes,
after which it remains permanently ON.
In order to vary this time repeat the described procedure. If you
want to obtain an INFINITE WORK TIME and use the limit switch,
you will need to carry out the procedure by keeping the MODE key
pressed for less than 1 second and the signal will be given from the
W.T OFF LED.

4.5 - Setting automatic closure

Programming of the automatic closure time from 4 seconds to 2 min.
The unit is provided with an deactivated automatic reclosure.
Setting automatic re-closing time:
1) Press 3 times on the SELECTION key, the A.R led is now
flashing.
2) Press the MODE key: from this moment the number of flashig
corresponds to the closure time in seconds. The first 3 seconds of
pressing the key activates the closure; on releasing the key the au-
tomatic closure and the A.R LED remains lit. The re-closure occurs
also in the pedestrian function if active.
The unit starts counting the reclosure as soon as it has reached a
condition of complete opening, or as soon as the opening operatio-
nal time is finished, or the opening control is activated. The reclosu-
re takes place in no other intermediate phase of automation stop.

4.6 - Setting pedestrian function

The control box is supplied with the pedestrian feature deactivated.
In order to use this function, the use of the 2nd transmitter channel is indispensable (see paragraph 4.3)
Activation and setting:
1) Press 4 times on the SELECTION key, CD. and W.T are lit.
2) Press the MODE key, the CD. and W.T led are now flashing.
3) Wait for the three LED to turn on.
4) Press SS key, the automation starts to open and continue to open
until SELECTION or MODE key are pressed. Once release the key,
the motor stops and that position is memorised as pedestrian run.
Now, the second channel learned (2) will manage the pedestrian fun-
ction. If we want to change the pedestrian run, it's enough to repeat
the procedure described upside.
To disable the pedestrian function:
Repeat step tot the point 2 (Led CD. and W.T FLASHING).
Pressing the MODE key again will disable the function with the
18
PRESS 2 TIMES SELECTION
MODE
ATTENTION:
EVERY TIME THAT THE CONTROL UNIT IS TURNED ON THE
WORKING TIME IS RELOADED. THE FIRST STEP BY STEP
(SS). COMMAND IS ALWAYS OPEN EXchEPT WHEN THE
OPEN LIMIT SWITCH ( IF PRESENT) IS ACTIVATED.
PRESS 3 TIMES SELECTION
MODE
To disabile the automatic closure, follow the procedure keeping
the MODE KEY PRESSED FOR LESS THAN 3 SECONDS. On
releasing the A.R remains off.
ENABLE
PRESS 4 TIMES
SELECTION
W.T
W.T
W.T
CD.
MODE
relative signalling of the two LEDS: CD. and W.T ON for a few
seconds. If disabled, each time it is re-enabled, it will be necessary
to reset the time.
W.T
W.T
A.R
A.R
SETTING THE PEDESTRIAN
FEATURE
1
2
4
3
SELECTION OR MODE