END OF SEASON
·
Please drain the water.
·
Keep the unit running in Fan mode for two hours until the inside of the unit is dry.
·
Turn off the unit and unplug it.
·
Clean the air filter and after dry it thoroughly, reinstall it.
·
Remove the exhaust pipes and keep them carefully.
·
Wrap the unit with the plastic bag and keep it in a dry place.
TROUBLE SHOOTING
Before contacting professional service, check it first yourself referring to the followings
Problem
The air conditioner does not
function.
The air conditioner restart
frequently
The unit is too noisy
No work of compressor.
Cautions: Switch off the unit and unplug it immediately if anything abnormal
happens. Then contact a qualified electrician. Above data without advance notice for
product improvement
TECHNICAL DATA
Power supply
Cooling medium
Cooling efficiency
Power consumption
Maximum allowed overpressure
Maksymalne dopuszczalne ciśnienie
Air flow
Fuse parameters of the machine
Type: 5ET or SMT Voltage: 250V Current: 3.15 A
•
24
EN
Cause
No power supply.
flashes on the display screen
In direct sunlight
Windows or doors open, many
people or a heat source in the
room.
Dirty filter
Air inlet or air outlet blocked
Unit stands uneven.
Self protect of compressor
suction
pumping
Solution
Connect to power supply outlet
and switch on
Drain water
Close curtains.
Close doors and windows, remove
the heat source
Clean or replace the filter(s).
Remove the blockage
Place on an even, solid surface
(less vibration).
Wait for 3 minute and restart
again after the descend of
temperature
220-240V~ 50Hz
R290/210g
9000Btu(2.10KW)
1010W
0.6MPa
1.8MPa
3.0MPa
350m³/h