6.2 INSPECTION AND MAINTENANCE PLAN
Burn pot
Ash bin/Compartment
Glass
Door and burn pot gaskets*
Flue*
Fans*
Exchanger and fumes circuit*
responsibility of the Authorised Service Centre.
(*)
(a)
At least once a year or after each 4 tons of fuel burned
7 DECOMMISSIONING AND DISPOSAL
Decommissioning and disposal of the stove are the exclusive responsibility of the owner, who must
act in accordance with the laws in force in the country where the stove is installed with regards to
safety and environmental protection.
The stove may also be dismantled and disposed of by companies authorised to recover and dispose
of the materials in question.
INSTRUCTION: always observe the standards in force in the country where the stove is decommissioned
as regards disposal of the materials and the waste disposal report where required.
IMPORTANT: All dismantling operations for decommissioning the stove must be performed when the
stove is off and disconnected from the power supply.
•
remove all electrical equipment;
•
separate the batteries fitted on the electronic boards;
•
have the structure of the stove scrapped by an authorised company;
IMPORTANT: Dumping the stove in accessible areas represents a serious hazard to people and
animals.
Liability for any harm caused to people or animals always lies with the owner.
When decommissioning the stove the ce mark, this manual and other documents relating to this stove
must be destroyed.
The picture of the bin crossed is labelled on the equipment, and it means that when the device is out
of use it has to be kept separated by other wastes.
On the basis of Article 13 by Legislative Decree n°151 of 25th July 2005 actuation of the European
Directive 2002/96/CE of 23rd February 2003 on waste electrical and electronic equipment. It is
connected to the policy and action which aim to the prevention of waste electrical and electronic
equipment,named RAEE, and in addition, the reuse, recycling and other forms of recovery of such
wastes so as to reduce the disposal of waste. It also seeks to improve the environmental performance
of all operators involved in the life cycle of electrical and electronic equipment.
36
WHENEVER
WEEKLY
STARTED
X
X
X
004776370 - 31/01/2019 - PALAZZETTI - PN - ITALY
1 YEAR
(a)
X
X
X
X