Colling fan
6
When the RB655 tool is used under cold temperature (below 0˚C/30F), you may find the following
phenomenon.
A. The part that catches the tie wire does not fully open after the tying action is completed, and it is hard
to pull out the tool from the tied wire.
B. The tie wire is not cut.
The self-warm-up program is installed to the RB655. Running the self-warm-up program helps to solve
the phenomenon above.
How to run the self-warm-up program
2. TURN THE POWER SWITCH ON
1. KEEP PULING THE TRIGGER
Regarding Cooling Fan
5
The tool is equipped with a cooling fan. When the temperature inside the tool is 0˚C
(32F) or higher and the trigger is pulled, the fan starts running. The fan stops
automatically when one minute passes after the last tying action. If the temperature
inside the tool is 0˚C (32F) or lower, the fan does not run even when the trigger is
pulled.
Self-warm-up program
Step 1.
Turn the main switch off and remove the tie wire from the tool.
Step 2.
Set Torque dial at position "8" (maximum position).
Step.3
Keep pulling the Trigger and turn the Power switch on. The twisting part of the RB655
automatically conducts the twisting action for 60 seconds, then stops.
19