7. INSTALL TRANSITION TO ROUGH-IN PLATE

Model 423, 424, 427, 453, or 454
Attach transition (if required) to blower rough-in plate.
Use duct tape to make all joints secure and air-tight.
NOTE:Model RM325H blower plate connects directly to 7" round ductwork
without a transition.
Exterior blower models utilize a model 332KR rough-in plate
which connects directly to 10" round ductwork without a transition.

8. INSTALL THE ROUGH-IN PLATE TO THE HOOD

Run power cable to installation location. Refer to the instructions
included with the selected blower or rough-in kit (sold separately) for
details on installing the rough-in plate. Install the rough-in plate so that
the wiring box is located on the right side as you are facing the hood.
For ducting through back of hood, remove existing plate from inside
back of hood and attach to inside top of hood to cover hole. Secure to
threaded studs with same (4) nuts.
For ducting through top of hood, existing plate remains in place on
inside back of hood.
Connect ducting to transition or rough-in plate as you are installing the
rough-in plate. Use duct tape to make all joints secure and air-tight.

9. CONNECT THE WIRING

Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and
standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power
from being switched on accidentally.
Remove wiring cover from rough-in plate and set aside.
Remove appropriate knockout from rough-in plate. As you are installing the rough-in plate, feed 6" of power cable through knockout
opening and attach cable to wiring box with appropriate connector.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover.
HD0049