Installer setup
Setup functions
0500
Furnace filter
change reminder
0510
Humidifier pad
change reminder
0520
UV lamp change
reminder
0530
Adaptive Intelligent
Recovery™
0540
Program periods
0580
Compressor
protection
0600
Heat temperature
range stop
0610
Cool temperature
range stop
0640
Clock format
0650
Extended fan
timer (heat)
0660
Extended fan
timer (cool)
0670
Keypad lock
0680
Heat temperature
control
0690
Cool temperature
control
0700
Temperature
display offset
0710
RESET
Settings & Options
0
Off
1
10-day run time (about 1 month)
2
30-day run time (about 3 months)
3
60-day run time (about 6 months)
4
90-day run time (about 9 months)
5
120-day run time (about 1 year)
6
365-day run time (about 3 years)
0
Off
1
90 calendar days
2
180 calendar days
3
365 calendar days
0
Off
1
365 calendar days
1
On
** See page 11
0
Off
4
4 program periods (Wake, Leave, Return, Sleep)
2
2 program periods (Wake, Sleep)
5
5 minute compressor off time
[Other options: 0, 1, 2, 3 or 4-minute off time]
90 Max. heat temperature setting is 90°F (32°C)
[Other options: 40-89°F (4°C to 32°C)]
50 Min. cool temperature setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
12 12-hour time (i.e., "3:30 pm")
24 24-hour time (i.e., "15:30")
0
Off
90 Fan runs for 90 seconds after call for heat ends
0
Off
90 Fan runs for 90 seconds after call for cooling ends
0
Keypad unlocked (fully functional)
1
Partially locked (access to temperature settings only)
2
Fully locked
2
Standard temperature control (recommended)
1
Choose if room is warmer than set temperature
3
Choose if room does not reach set temperature
2
Standard temperature control (recommended)
1
Choose if room is cooler than set temperature
3
Choose if room does not reach set temperature
0
Thermostat displays actual room temperature
[Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)
0
No reset
1
Reset installer options & program schedule to factory
default (only date and time settings are retained)
VisionPRO
TM
(factory default in bold)
** See page 11
TH8000 Series