GB
out his job), for the customer (if envisioned) and
for routine maintenance interventions.
- A space of at least 50 cm must be left in
correspondence with the ventilation grids for the
SDVVDJH RI DLU ¿J
- If the product unit is positioned at the centre of
D URRP SUHSDUH DQ XQGHUÀRRU FKDQQHO RU DQ
overhead arrival tract for the power supply cable.
Position the counter in the space established,
remembering to remove the two planks on the base
RI WKH VDPH EHIRUH SRVLWLRQLQJ GH¿QLWLYHO\
The counter must be positioned in a way that it is
perfectly level (Fig. 7).
'XULQJ LQVWDOODWLRQ LW PXVW DOVR EH YHUL¿HG WKDW
- there is sufficient air circulation around the
counter, but not currents;
- The counter is not in the vicinity of hot air sources;
LW LV QRW H[SRVHG WR GLUHFW VXQOLJKW ¿J
- the condenser cooling air passage grids are not
obstructed;
- any air conditioning or room heating is not aimed
towards the display unit.
NOTE!
The above-mentioned indications
must be respected in order to prevent
malfunctioning, which will not be covered
by the warranty.
Fig. 7
A
2.4 ENVIRONMENTAL SPECIFICATIONS
ATTENTION!
The display unit can operate in a
maximum environment temperature of
32°C and 60% relative humidity, if the
appliance undergoes regular scheduled
maintenance.
2.5 MOUNTING THE FEET
ATTENTION CRUSHING HAZARD
Operation performed by 2/3 persons.
:KLOH WKH ERG\ LV OLIWHG XVH D ER[ ZUHQFK ¿J
to unscrew the feet and remove the wooden cross
beams.
ATTENTION!
This operation must be performed with
great care, inserting the safety elements
during the operation.
Re-mount the feet using the lock nut (Fig. 9) and
screw them to half way of their stroke (they will be
adjusted and tightened in the successive phases).
3RVLWLRQ WKH ERG\ LQ LWV GH¿QLWLYH SRVLWLRQ
Adjust the feet to take the body to the correct height
and make it level (Fig. 7, Pos. A)
Once level, tighten the lock nuts on the feet.
NOTE:
the feet can be extracted to a maximum
of 20 mm.
Fig. 8
29
Fig. 9