Installation Instructions
®
Rolux
Vertical Discharge Vent System
1
Identify the vent location
NOTE
Cover the top of the heater
to prevent debris from entering.
2
Cut to fit
I
B
A
II
IV
B

C
III
Determine the location where the roof
discharge terminal will be installed. Taking
into account the angle of the roof, cut the
hole with a dimension that allows the
vertical discharge roof terminal to be
installed (6"x6" hole for flat roof, 9"x6" hole
for 12/12 pitch, or 12"x6" hole for 16/12
pitch).
The terminal can be
shortened by removing the
components A+B+C, and
then shortening both the
inside and outside pipes with
the same length X.
Re-assemble the terminal
by attaching the components
A, B, and C in the correct
order. Tighten component
B securely.