CONTROL

1. GENERATOR SWITCH

2. RECOIL STARTER

To start the engine, pull the starter grip lightly until resistance
is felt, then pull briskly.
Do not allow the starter to snap back against the engine.
Return it gently to prevent damage to the starter.

4. CHOKE LEVER

The choke lever is used to provide an enriched fuel mixture when starting a cold engine.
Slowly put the choke lever to "OPEN" position after the engine is heated.
5. AC CIRCUIT BREAKER / OVERCURRENT PROTECTIOR
The overload current will automatically switch off circuit breaker to avoid short circuit of the
load or overload. If the indicator of AC Overcurrent Protector is raised, the Over-current
Protector is now in the "OFF" position. Press the button of AC Over-current Protector to
the "ON" position again a few minute later. If the circuit breaker is switched OFF
automatically, switch the circuit breaker ON again.
6. OIL ALERT SYSTEM (Except PMV1200)
The oil alert system is specially designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. When the oil level in the crankcase falls down
below a safe limit, the oil alert system will automatically shut down the engine (though the
generator switch still remain in the ON position), so that the engine can't be damaged
resulting from the insufficient amount of the oil.

3. FUEL VALVE

The fuel valve controls fuel flowing from the fuel tank
to carburetor. Be sure to return the lever to "OFF"
after stopping the engine.
7