Key Description
Keypad Zone Sending
[1]
Keypad Zone Requires
[2]
Ω
1K
EOL Resistor
Keypad Zone Set to
[3]
On-Board Keypad Tamper
[4]
Supervision
Status LED Follows Arming
[5]
Status of
Multiple Zone Display
[6]
Scrolling Zone Display
[7]
Time Format
[8]
Keypad Zone Sending
Section [2] — Option [1]
Off = Disabled
On = Enabled (default)
The Keypad Zone Sending option must be enabled when:
• You are using both of the control panel's keypad zones
and at least one keypad zone is from a 1641BL LCD
Keypad module.
• You are using the keypad zones of other types of keypads
and the keypad zone definition of the 1641BL LCD Keypad
module (keypad zone 1 or zone 2; Section [2] Option [3])
matches that of another connected keypad.
Table 1: Keypad Options
OFF
Disabled
No
Keypad Zone 1
Disabled
Partition 1
Disabled
Disabled (only if
[6] = ON)
International
ON
Enabled
Yes
Keypad Zone 2
Enabled
Partition 2
Enabled
Enabled
US (a.m./p.m.)
Bold = Default
Spectra 1641BL 5