Meta System WHAD 800 Manual De Uso página 10

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 24
Output wave form
With mains operation
With battery operation
Type of operation
Electrical output specifications with mains operation
Nominal output voltage
Nominal output frequency
Output current with linear load PF=0,7
Tolerated crest factor on output
current
Nominal output power
Active output power with linear or
non-linear load PF=0,7
Total harmonic distortion of output voltage
with linear nominal load
Total harmonic distortion of output voltage
with non-linear nominal load PF=0,7
Overload capacity
Power factor range with applied load
Number of output phases
AC-AC conversion efficiency with linear load
PF = 1 and charged batteries
With 50% load
With 75% load
With 100% load
Electrical output specifications with battery operation
Nominal output voltage
Output frequency
Nominal output power
Active output power with linear or
non-linear load PF = 0,7
Total harmonic distortion of output voltage
with non-linear nominal load PF=0,7
Overload capacity
Power factor range tolerated with
nominal load
DC-AC conversion efficiency with linear load
PF=1 and charged batteries
With 50% load
With 75% load
With 100% load
WHAD 800
WHAD 1000
Sinewave
Sinewave
No break, on line UPS with passing neutral and double
conversion
230V stepwise setting with step of 1V in the range of 184V to 255V
50Hz / 60Hz synchronized
3,5 Arms
4,4 Arms
3,5
3,5
800 VA
1000 VA
560 W
700 W
< 0,5%
< 1%
300% for at least 1 second without bypass intervention
200 % for at least 5 seconds without bypass intervention
150 % for at least 30 seconds without bypass intervention
From 0,7 to 1
Single phase
80%
84%
90%
230V +/-1%
50Hz/60Hz +/-1%
800 VA
1000 VA
560 W
700 W
< 1%
200% for 15 seconds
from 0,7 to 1
80%
80%
80%
18
Battery operation
Approximate autonomy in minutes with
charged batteries
50% of the applied load
80% of the applied load
Recharge time up to 90% of total load
Technical data and quantity of batteries
Reserve signal
Minimum voltage for battery operation
Average battery life
Bypass Specifications
Type of bypass
Standards
Safety
Electromagnetic compatibility:
Immunity - emission
Performance and features
WHAD 800
WHAD 1000
29 min.
23 min.
17 min.
13 min.
5-6 hours according to level of discharge
N° 4 pcs 12V 5,4Ah, sealed, lead-acid, maintenance free
batteries connected in series
From 32.2V to 36V can be programmed by operator
From 27V to 31.5V with automatic selection according to
load or can be programmed by operator
3-6 years according to use and working temperature
Warning !
The batteries in the UPS are subject to a reduction in
capacity according to their age (a feature of lead batteries
declared by their manufacturer in the technical manual). For
example, the reduction in the capacity of a 4-year-old battery
can reach 40% with a proportional reduction of autonomy
times of the UPS when operating in battery mode.
Static and Electro-mechanical
Conforms to standard EN 62040-1-1
Conforms to standard EN 50091-2
Conforms to standard EN 62040-3
19