Installer Parameter Description - Watts BT-D03 RF Guía De Usuario

Ocultar thumbs Ver también para BT-D03 RF:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 102
ENGLISH

8. INSTALLER PARAMETER DESCRIPTION

To access to these installer parameters, installer has to go to user parameter number 15.
After, he presses and holds validation key
holding
button
BT-D03-MOI-FR-W-EN-06-19
EN
Accessing to installer parameters
Selecting temperature sensor used for the regulation:
- AIR: regulation with internal sensor
- Amb: regulation with external sensor
- FLR: regulation on floor sensor (external sensor of remote,
only when thermostat is connected to master) or embedded
sensor on receiver
- FLL: regulation with floor sensor and air sensor
Factory setting value: Air
Displaying of measured temperature by internal sensor:
If "Err" is displayed, internal sensor is damaged.
Displaying of measured temperature by external sensor:
➤ FLOOR temperature / AMBIENT temperature
If "Err" is displayed, external/ambient sensor isn't connected
or damaged.
Displaying of measured temperature by floor sensor
connected to receiver (only with specific bidirectional
system)
If "Err" is displayed, thermostat isn't associated to a received
with floor sensor or this sensor is damaged.
Lower limit of floor temperature (FL.L)
This value is used when parameter 20 is FLL
Factory setting value: "no": not activated
Other values: 5°C to "FL.H"
High limitation of floor temperature (FL.H)
This value is used when parameter 20 is set on "floor limit"
FLL.
Factory setting value: "no": not activated
Other values: "FL.Lo" to 40°C
during 5 seconds:
holding
button
Other values: Amb / FLL / FLR
Installer
parameters
releasing
button
15

Publicidad

Tabla de contenido
loading

Tabla de contenido