Wire Connector
[ Conexión del cable ]
TA2JG250 / 3VL9425-4TF01
3TA2JG250 / 3VL9425-4TF31
4TA2JG250 / 3VL9425-4TF41
TC2JG250 / 3VL9425-4TF11
2TA2LG600LD / 3VL9460-4TY21
3TA2LG600LD / 3VL9460-4TY31
2TA2LG600LN / 3VL9460-4TX21
3TA2LG600LN / 3VL9460-4TX31
8 mm
5/16"
3TC2LG600LD / 3VL9460-4TY61
3TC2LG600LN / 3VL9460-4TX61
Bestell-Nr. / Order No.: 3ZX1012-0VL68-5AA4
Technical Support:
Subject to change without prior notice
Siemens Industry, Inc. , Norcross, GA 30092 U.S.A.
Tensión peligrosa.
Tensión peligrosa.
Puede causar la muerte o lesiones graves.
Puede causar la muerte o lesiones graves.
Desenergice totalmente antes de instalar o darle servicio.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
energizar el interruptor.
Wire Size
[ Rango Cable ]
Cu / Al
3/0 – 4/0 AWG
8 mm
[ 95 mm² ]
OR
5/16"
Cu / Al
250 kcmil
[ 120 mm² ]
Cu Only
3/0 – 4/0 AWG
8 mm
[ 95 mm² ]
OR
5/16"
Cu Only
250 kcmil
[ 120 mm² ]
Cu / Al
2 AWG
[ 35 mm² ]
8 mm
Cu / Al
or
1 – 4/0 AWG
5/16"
[ 50 - 95 mm² ]
Cu / Al
250 – 500 kcmil
[ 120 - 185 mm² ]
Cu / Al
600 kcmil
[ 240 - 300 mm² ]
Cu Only
2 AWG
[ 35 mm² ]
Cu Only
or
1 – 4/0 AWG
[ 50 - 95 mm² ]
Cu Only
250 – 500 kcmil
[ 120 - 185 mm² ]
Cu Only
600 kcmil
[ 240 - 300 mm² ]
For Support in Europe refer to :
Internet: www.siemens.de/lowvoltage/technical-assistance
Toll Free: 1-800-241-4453
UL 486A - 486B
Req. Wire Stranding
( Cable )
CU / AL
CU
Class B
Class C
19 STRANDS
37 STRANDS
37 STRANDS
61 STRANDS
19 STRANDS
37 STRANDS
61 STRANDS
37 STRANDS
7 STRANDS
19 STRANDS
37 STRANDS
19 STRANDS
37 STRANDS
61 STRANDS
61 STRANDS
91 STRANDS
19 STRANDS
7 STRANDS
19 STRANDS
37 STRANDS
37 STRANDS
61 STRANDS
61 STRANDS
91 STRANDS
6 / 6
Tension dangereuse.
Tension dangereuse.
Danger de mort ou risque de blessures graves.
Danger de mort ou risque de blessures graves.
Couper l'alimentation de l'appareil et barrer avant de
Couper l'alimentation de l'appareil et barrer avant de
travailler.
travailler.
Remplacez touts les couverts avant que
Remplacez touts les couverts avant que
l'approvisionnement de pouvoir soit alimenté.
l'approvisionnement de pouvoir soit alimenté.
Torque
[ esfuerzo de
Wire Strip Length
torsión ]
[ Quitar ]
"D"
[ 18 mm ]
275 lb. in.
[ 31 Nm ]
[ 37 mm ]
[ 25.4 mm ]
375 lb. in.
[ 42.4Nm ]
[ 50 mm ]
GWA 4NEB 179 6874-10 DS 05
Internet: www.usa.siemens.com/powerdistribution
© Siemens Industry Inc. 2010
"B"
.71"
"C"
1.46"
"B"
1.0"
"C"
1.97"
806874A04