Electrical data
Hydraulic data
Range of use
Weight
The pump which does not stand on a base cannot support the weight of the pipes, which must be
supported in some other way.
4. MANAGEMENT
4.1 Storage
All the pumps must be stored in a dry covered place, with possible constant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the time of installation.
4.2 Transport
Avoid subjecting the products to needless impacts and collisions.
4.3 Weight and dimensions
The adhesive plate on the packaging indicates the total weight of the pump and its dimensions.
5. WARNINGS
The pumps must never be carried, lifted or allowed to operate suspended from the power cable; use
the handle provided.
The pump must never be allowed to run when dry.
The pump must be positioned so that the holes on the suction side cannot be partially or totally clogged by dirt.
The sealing device contains lubricant which is non-toxic but which may alter the characteristics of the water, in the
case of pure water, if the pump were to have any leaks.
The pump has a thermal overload safety device. In the event of any overheating of the motor, this device
automatically switches off the pump. The cooling time is roughly 15 to 20 minutes, then the pump automatically
comes on again. If the overload cutout is tripped, it is essential to identify and deal with the cause of the overheating.
See Troubleshooting.
6. INSTALLATION
Screw on the elbow with hosetail fitting provided in the packaging. For the dirty water version only the fitting for 1''1/2
pipes; if you want to use a pipe with a larger diameter, change the elbow coupling. Use a pipe tightening clamp to secure
the pipe to the fitting.
It is advisable to use pipes having an internal diameter of 38 mm to avoid the decrease of pump performance and the
possibility of blocking.
If the bottom of the trap where the pump is to be placed is particularly dirty, a raised support should be provided so as
to avoid blocking of the suction grid (Fig.1)
Totally immerse the pump in the water.
Model
P1 Rated absorbed power [W]
Mains voltage [V]
Mains frequency [Hz]
Current [A]
Capacitor [µF]
Capacitor [Vc]
Max. flow rate [l/min]
Max. head [m]
Max. head [bar]
Max. immersion depth [m]
Min. AUT starting height [mm]
Residual water height [mm]
Length of power cable [m]
Type of cable
Grade of motor protection
Insulation class
Liquid temperature range [°C]
according to EN 60335-2-41 for domestic
use
Max. particle dimension [mm]
Max. ambient temperature [°C]
DNM GAS
Net/Gross weight approx. [kg]
ENGLISH
Draining dirty water
1000
1000
1 ~ 230 AC
12.5
450
260
H05 RNF
IP X8
0 °C / +35 °C
Ø 38
+40 °C
1'' 1/2 F
8.2 / 10.1
Table 3
2
50
4.2
12
1.2
7
50
50
10
F