T
ROUBLESHOOTING
For any problems not listed below, call your local distributor or contact our Service Department toll free at 888-867-
3235.
PROBLEM
Unit does not operate
Change light illuminated
Blower wheel not turning
S
PECIFICATIONS
MODEL
TYPE
VARIABLE CFM
HEIGHT
WIDTH
DEPTH
USE WEIGHT
SHIP WEIGHT
07-01489C 2012-05 Warranty 07-00419
READ AND SAVE THESE INSTRUCTIONS
Note:To be assured of true HEPA filtration, change the HEPA filter after
every water damage job, or when the indicator light comes on; whichever occurs
first.
When using the DefendAir HEPA 500 for remediation:
After every job
• Replace both the filters to prevent cross-contamination.
• Clean the unit thoroughly (vacuum and damp wipe per IICRC S520, 10.11)
CAUSE
• No power to machine
• Switch not turned on
• No power to outlet
• GFCI Tripped
• Primary filter is full
• Air intake restricted
• Obstructed blower
• Loosen blower wheel set screw
F284
115 V
250-500 CFM
24.6" (62.5 CM)
26.2" (66.5 CM)
18.2" (46.2 CM)
44 (19.9 KG)
46 (20.9 KG)
after each job before removing it from the containment area to avoid cross-
contamination. Pay particular attention to the area around the air intake. Let
the unit dry before installing clean filters.
• Plug in the unit; check power at outlet
• Turn on the switch
• Reset circuit breaker/GFCI
• Reset circuit breaker/GFCI
• Replace the filters; refer to Maintenance section
• Eliminate bends/kinks in ducting, or remove
• Remove obstruction
• Tighten set screw
CONTROLS
FILTERS
HANDLE
HOUSING
POWER 115V
CORD LENGTH
SAFETY
FREQUENCY (HERTZ)
6
SSSOLUTION
ducting
TOUCHPAD
PRE-FILTER
(P/N 13-00199)
PRIMARY HEPA
P/N (F321)
ROTOMOLDED
ROTOMOLDED
3 AMPS
25 FT (7.6 M)
UL LISTED
60
Dri-Eaz Products, Inc.